Capacity | 1KVA/0.8KW | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 10KVA/8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
UPS Structure | Double Conversion High Frequency Online | |||||||
Appearance | Tower or Rack-Mount Type | |||||||
Overall Efficiency (AC-AC ) | > 99% | |||||||
Noise(In 2 meters) | <50dB | |||||||
Working Temp | 0-40ºC | |||||||
Storage Temp | -15~ 60ºC(Without BATs) | |||||||
Humidity | < 95% Non-Condensing | |||||||
Safety Standard | GB/T14715 | |||||||
EMC Standard | EN50091-1/2 | |||||||
Protections | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low | |||||||
Parallel Redundancy | None | Available | ||||||
DC Start | Available | |||||||
Generator Compatibility | Available | |||||||
Manual Maintenance Bypass | None | |||||||
Display | LCD/LED: UPS Status, INV Status, Bypass Status, BAT Status, BAT %, Load %, Fault Messages | |||||||
Alarm | Auto | |||||||
Mute | Auto | |||||||
Rectifier Specification | ||||||||
Input Voltage Range | 100% Load:160~300Vac,50%Load:115~300Vac | 175 ~ 280Vac | 304 ~ 478Vac | |||||
Input Frequency Range | 45-65 Hz(Auto-Tracking) | |||||||
Input PF | 0.99 | |||||||
THDI | < 5% | |||||||
Output Specification | ||||||||
Output Voltage | 220Vac | |||||||
Output PF | 0.8,0.9 optional | |||||||
Output Voltage Regulation | 220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change) ;220Vac±3%(100-0% Sudden Change) | |||||||
Output Freq.(Online Mode) | When 46Hz ≤Input Freq.≤ 54Hz,Input Freq.=Output Freq.;When Input Freq.<46Hz or >54Hz, Locked at 50Hz | |||||||
Output Freq. (BAT Mode) | 50Hz± 0.2% | |||||||
Output Waveform | Pure Sine Wave | |||||||
Distortion | <1%(Linear Full Load),<3%(None-Linear Full Load) | |||||||
Overload | > 125%: More than 1 min | > 120%: More than 1 min | ||||||
> 150%: 300 ms transfer to bypass | > 150%: 300ms transfer to bypass | |||||||
Crest Ratio | 3:01 | |||||||
Efficiency | >90% | |||||||
Short-Circuit | Circuit Auto Protection,Output Voltage/Current 0 | |||||||
Output Abnormal | INV Output Auto-Locked Protection | |||||||
Noise Suppression | EMI/RFI Wave filter | |||||||
BAT Low | Shutdown Protection | |||||||
Dynamic Response | 3% at full load,recovering in 20ms | |||||||
Auto-Restart | Available | |||||||
Software Control | Available | |||||||
Bypass Specification | ||||||||
Static Bypass Transfer Time | 0ms | |||||||
Static Bypass Range | 80Vac± 5% ~285Vac±5% | |||||||
Bypass -> INV Transfer Time | 2ms | |||||||
Battery Specification | ||||||||
Type | Sealed Lead Acid Maintenance Free | |||||||
Backup time | 5-10min | 5-10min | 5-10min | 5-15min | 5-15min | 5-15min | ------------ | -------------- |
Ext. Model Rate Volts/Units | 36Vdc | 72Vdc | 96Vdc | 192Vdc | 192Vdc | 192Vdc | 192Vdc | 192Vdc |
Std. Model Charging Current | 1A | 1A | 1A | 1A | 1A | 1A | 1A | 1A |
Ext. Model Charging Current | 6A | 7A | 7A | 7A | 7A | 7A | 7A | 7A |
Communication Specification | ||||||||
Communication Port | Rs232 (Std.);/SNMP/RS485/ Dry Contact (Optional Accessory) | |||||||
Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control | |||||||
Physical Parameters | ||||||||
Size mm(D×W×H) | 355x145x220 | 433x190x318 | 433x190x318 | 6/10K Std.:500×240×620 | 500x240x620 | |||
6/10K Ext.:500×240×460 | ||||||||
Net weight Kg | 9.8/6.5 | 18.5/10.5 | 21/11.5 | 57/20 | 67.5/22 | 27 | 35 | 35 |
Size mm(RM D×W×H) | 430×450×88 | 430×450×177 | -------- | ---------- | ---------- | |||
Net weight Kg | 7 | 10 | 14 | 18 | 20 | -------- | ---------- | ---------- |