AC Resonant Test System

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hubei

  • Validity to:

    Long-term effective

  • Last update:

    2020-12-08 14:11

  • Browse the number:

    149

Send an inquiries

Company Profile

Wuhan Goldhome Hipot Electrical Co., Ltd

By certification [File Integrity]

Contact:goldhomehipot2020(Mr.)  

Email:

Telephone:

Phone:

Area:Hubei

Address:Hubei

Website:http://www.hvcablehipot.com/ http://goldhomehipot2020.304hmtg.com/

Product details

AC Resonant Test System 4000kvA/800kV


Product description


AC Resonant test system is mainly used for conducting the on-site AC dielectric test for electric equipment with large capacity, including medium-low voltage, high voltage and ultra-high voltage XLPE, GIS, motor stator, large-sized transformer and electric capacitor.

The series variable frequency resonant system is to change the system inductance and test frequency to make circuit in resonant condition. Its electric circuit is shown in Fig.1. The adoption of variable frequency resonant technology reduces the capacity of power source and the weight of equipment, which facilitates on-site test.

Fig.1

Hot tag: series resonance test set,ac dielectric test system supplier,resonance hipot test device,cable withstand voltage test device manufacturer.

 

4000kvA/800kV Variable Frequency Resonant test set applied test object 


Device combine Test object

Reactor: 1000kVA/200kV  4 pcs

Exciting transformeroutput selection

110kV,630mm2,3km power cable

4 pcs in parallel

6kV

220kV,630mm2,1.2km power cable

4pcs,2 in series, 2group in parallel

 12kV

110 kV power system、busbar、GIS,etc

2 pcs in series

12kv

220 kV power system、busbar、GIS,etc

3 pcs in series

12kv

500 kVpower system、busbar、GIS,etc

4 pcs in series

36kv


Advantage


1. The required power supply capacity is greatly reduced. The series resonant power supply uses the resonant reactor and the capacitor resonance to generate high voltage and large current. In the whole system, the power supply only needs to provide the part of the system that consumes power. Therefore, the power required for the test is only 1/Q of the test capacity. 

2.The weight and volume of the equipment is greatly reduced. In the series resonant power supply, not only the bulky high-power voltage regulating device and the ordinary high-power power frequency test transformer are omitted, but also the resonant excitation power supply only needs to test the capacity of 1/Q, so that the weight and volume of the system are greatly reduced, generally 1/10-1/30 of the common test device.

3. Improve the waveform of the output voltage. The resonant power supply is a resonant filter circuit, which can improve the waveform distortion of the output voltage and obtain a good sinusoidal waveform, effectively preventing the harmonic breakdown of the testing sample from being accidentally broken.

4. Prevent large short-circuit currents from burning the point of failure. In the series resonance state, when the insulation weak point of the sample is broken, the circuit is immediately detuned, and the loop current rapidly drops to 1/Q of the normal test current. When the parallel resonance or test transformer method is used for the withstand voltage test, the breakdown current immediately rises several tens of times. Compared with the two, the short-circuit current and the breakdown current are hundreds of times different. Therefore, series resonance can effectively find the insulation weakness, and there is no big short-circuit current burn failure point.

5. No recovery over voltage will occur. When the testing sample breaks down, the high voltage also disappears immediately due to the loss of the resonance condition, the arc is extinguished immediately, and the recovery voltage is re-established for a long time. It is easy to disconnect the power supply before reaching the flash voltage again. This voltage recovery  is an intermittent oscillation process of energy accumulation,  and the process is long,  no recovery over voltage occurs.


Product main parameter


Item

Configuration

Main parameter

Quantity

1

High voltage reactor

JLB-200kVA/6kV12kV/36kV/0.2kV/0.4kV

1set

2

Variable-frequency power source 

CHXB-F-200kW/0.22/kV/0.38kV

1 set

3

High voltage reactor

DK-1000kVA/200kV

4 sets

4

High voltage reactor

FCR-800kV/750pF

1 set

5

Testing cable


1 set

6

Insulating support


1set

All Specifications can be customized according to client’s requirements.


4000kvA/800kV Variable Frequency Resonant factory release test picture



Reference date of equivalent capacitances of common testing object of AC resonant test system


C=εΑ/d ,ε---permittivity of medium,Α---electrode area,d---Electrode distance
Appendix 1. List of electricity capacity of several common subjects

Testing object

Capacitance

Power transformer 1-100MVA

1-6MVA:3000-10000pF

10MVA:5000-12000 pF

20MVA:7500-15000 pF

60MVA:13000-20000 pF

100MVA:15000 Pf-20000 pF


300MVA:20000 Pf-30000 pF

CVT

3000-5000 pF

HV circuit breaker、CT、PT

100-1000 pF

Swichgear(common and SF6)

300-1000 pF

 high-pressure pipe

50-600 pF

Insulator

<100 pF

Insulation tool

10-100 pF

overhead conductor and bus(per meter)

8-10 pF

Appendix 2:35KV And 35kV below capacitance of cable

Cross-sectional area of the single conductor (mm²;)

18/20KV

6/6KV
6/10KV

8.7/10KV
8.7/15KV

26/35KV

μF/KM

μF/KM

μF/KM

μF/KM

25

0.1163

0.1922

0.1567

0.0992

35

0.1251

0.2116

0.1725

0.1061

50

0.1362

0.2357

0.1917

0.1150

70

0.1508

0.2693

0.2167

0.1263

95

0.1643

0.2999

0.2400

0.1368

120

0.1760

0.3266

0.2603

0.1460

150

0.1893

0.3570

0.2834

0.1563

185

0.2026

0.3873

0.3123

0.1665

240

0.2207

0.4296

0.3439

0.1805

300

0.2387

0.4706

0.3755

0.1945

400

0.2648

0.5311

0.4213

0.2146

500

0.2876

0.5839

0.4613

0.2321

630

0.3151

0.6481

0.5099

0.2533

Appendix 3:110KV、220KV capacitance of cable

110KV

220KV

Cross-sectional area of the single conductor(mm²;)

Capacitance(μF/KM)

Cross-sectional area of the single conductor(mm²;)

Capacitance(μF/KM)

240

0.136

240

0.110

300

0.147

300

0.117

400

0.165

400

0.125

500

0.182

500

0.134

630

0.201

630

0.144

800

0.224

800

0.155

1000

0.265

1000

0.180

1200

0.282

1200

0.190



1400

0.198



1600

0.204



1800

0.212



2000

0.222


FAQ


1.Can you provide the training for us?

Yes, we can provide free training for our client at our factory.

If you require the training on-site, we also can arrange accordingly.

We have 10 seasoned engineers who become our technical team, they flied many countries for client’s installation and commissioning!

2.What is your after-sale service

We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.

3.What’s the warranty period ?

Our warranty period is one year .

The product can be replaced within 1 month, can be repaired for free charge  for one year and maintenance for lifetime.

What is more, our warranty can be extended only charged small warranty fee.

http://www.hvcablehipot.com/